Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Dent ; 133: 104514, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37031885

RESUMEN

OBJECTIVES: To compare the clinical performance of occlusal splints printed from thermo-flexible resin with milled splints. METHODS: A parallel two-arm pilot trial was initiated. Forty-seven patients (n women=38) were recruited from a tertiary care center and randomized using an online tool (sealed envelope). Inclusion criterion was an indication for treatment with a centric relation occlusal splint due to bruxism or any form of painful temporomandibular disorder. Patients were excluded if they were younger than 18 years, unable to attend follow-up appointments, or required another type of splint therapy. Patients received either, a 3D-printed (intervention group, V-print splint comfort, VOCO) or a milled splint (control group, ProArt CAD splint, Ivoclar). Construction software Ceramill M-splint (AmannGirrbach), 3D-printer MAX UV 385 (Asiga) and milling unit PrograMill PM7 (Ivoclar) were used. Follow-up assessments were conducted after 2 weeks and 3 months. Outcome measures were survival, adherence, technical complications, patient satisfaction on a 10-point Likert scale, and maximum wear using superimposition of optical scans. RESULTS: After 3 months, 20/23 intervention group and 18/24 control group participants were assessed. All splints survived. Minor complications were small crack formations on 6 printed and 4 milled splints. Mean patient satisfaction was 8 (SD 1.7) for printed, and 8.1 (SD 2.3) for milled splints (r = 0.1, p = .52). Median maximum wear was highly dispersed with 153 (IQR 140) in posterior and 195 (IQR 537) in frontal segments of printed, and 96 (IQR 78) respectively, 123 (IQR 155) of milled splints, (both: r = 0.31, p = .084). CONCLUSIONS: Within the limitations of a pilot trial, 3D-printed and milled splints performed similarly in terms of patient satisfaction, complication rates and wear behavior. CLINICAL SIGNIFICANCE: Thermo-flexible material was proposed for 3D printing of occlusal splints to overcome mechanical weaknesses of previously available resins. This randomized pilot study provides evidence that this material is a viable alternative to milled splints for at least three months of clinical use. Further evidence on long-term use should be obtained.


Asunto(s)
Bruxismo , Ferulas Oclusales , Humanos , Femenino , Proyectos Piloto , Impresión Tridimensional , Férulas (Fijadores)
2.
PLoS One ; 17(5): e0268360, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35580131

RESUMEN

OBJECTIVES: This comparative study aimed to evaluate intraoral digital photography (IODP) as assessment-tool for DMFT and number of implants (IMPL) compared to clinical diagnosis (CLIN) in an elderly population with high restorative status. Secondary research questions were whether an additional evaluation of panoramic radiographs (PAN-X) or raters' clinical experience influence the agreement. METHODS: Fifty patients (70.98±7.60 years) were enrolled for standardized CLIN and IODP. The clinical reference examiner and ten blinded raters evaluated the photographs without and with a PAN-X regarding DMFT and IMPL. CLIN were used as reference standard and differences to IODP and IODP-PAN-X findings were analysed descriptively. To assess intra-rater agreement, pairwise Gwet's AC1s of the three diagnostic methods CLIN, IODP and IODP+PAN-X were calculated. RESULTS: Compared to a DMFT of 22.10±3.75 (CLIN), blinded raters evaluated a DMFT of 21.54±3.40 (IODP) and 22.12±3.45 (IODP+PAN-X). Mean values for "Decayed" were 0.18±0.52 (CLIN), 0.45±0.46 (IODP) and 0.48±0.47 (IODP-PAN-X), while 11.02±5.97 (CLIN), 10.66±5.78 (IODP) and 10.93±5.91 (IODP+PAN-X) were determined for "Missing" and 10.90±5.61 (CLIN), 10.43±4.85 (IODP) and 10.71±5.11 (IODP+PAN-X) for "Filled". IMPL were 0.78±2.04 (CLIN), 0.58±1.43 (IODP), 0.78±2.04 (IODP+PAN-X). Gwet's AC1 using the mode of the blinded raters' assessment of "Decayed", "Missing" and IMPL compared to CLIN ranged from 0.81 to 0.89 (IODP) and 0.87 to 1.00 (IODP+PAN-X), while for "Filled" and DMFT they were 0.29 and 0.36 (IODP) as well as 0.33 and 0.36 (IODP+PAN-X), respectively. Clinical experience did not influence the agreement. CONCLUSIONS: Assessment of "Decayed", "Missing" and IMPL by IODP showed almost perfect agreement, whereas of "Filled" and DMFT revealed fair to moderate agreement with clinical findings. Additional PAN-X-evaluation increased agreement compared to IODP-diagnostics alone. IODP for the assessment of DMFT and IMPL might be a suitable method in large-scale epidemiological studies, considering high agreement in total values and miscellaneous agreement at patient-level.


Asunto(s)
Fotografía Dental , Fotograbar , Anciano , Humanos , Prótesis e Implantes
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...